Ordinance No. 381ORDINANCE NO 381 AN ORDINANCE OF THE CITY COUNCIL OF THE CITY OF CYPRESS AMENDING SECTION 8-2 OF CHAPTER 8 OF THE CYPRESS CITY CODE AND ARTICLE 230 SECTION 230-1 OF THE NATIONAL ELECTRICAL CODE WHEREAS, the City Council of the City of Cypress has determined that the public health, safety, and welfare requires that utilities be placed underground wherever possible to protect and increase the public safety, to promote ease of access to said utility lines to promote ease of maintenance, to decrease the probability of interruption of service, to promote the least disturbance of residents of the City, to promote beautification within the City and to increase the enjoyment of the lives of the residents of the City of Cypre.s NOW THEREFORE, the City Council of the City of Cypress does ordain as follows SECTION 1 Article I, Section 8-2(h) of Chapter 8 of the Cypress City Code and Article 230, Section 230-1 of the National Electrical Code is hereby amended to read as follows (h) Article 230 Services Section 230-1 is hereby amended to read as follows "230-1 SCOPE The provisions of this Article shall apply to the conductors and equipment for control and protection of services -- circuits that conduct electric power from the supply system or plant to the premises to be served Regardless of the requirements of other Sections of this Code the minimum size of conduit, conductors,switch or circuit breakers for services shall not be less than the following: "(a) Commercial and store buildings A to G, inclusive, 100 sq ft and over The minimum service requirements for commercial and store buildings A to G, inclusive, 100 sq ft and over shall be Conduit 1" trade size Conductors 3 No 6 AWG Switch 60 Ampere Circuit breaker 50 Ampere "(b) Single-family dwellings, under 800 sq ft The minimum service requirements for single-family dwellings under 800 sq ft shall be• Conduit 1" trade size Conductors 3 No 6 AWG Switch 60 Ampere Circuit breaker 50 Ampere 'Provisions shall be made in the service panel for a minimum of 10 single pole over -current protective devices in addi- tion to the main switch or circuit breaker "(c) Single-family dwellings, 800 sq ft and over The minimum service requirements for single-family dwellings, 800 sq ft and over shall be: Conduit 1 trade size Conductors 3 No 1 AWG Switch 100 Ampere Circuit breaker 100 Ampere "Provisions shall be made in the service panel for a minimum of 20 single pole over -current protective devices in addition to the main switch or circuit breaker Ordinance N., 1R1 "(d) Duplex dwelling I occupancy For duplex dwelling I occupancy* be• "1 The combined minimum service requirements shall Conduit Conductors 12" trade size No 1 AWG "2 The minimum service for each individual occupancy shall be* Conduit 1" trade size Conductors 3 No 6 AWG Switch 60 Ampere Circuit breaker 50 Ampere "3 Service entrance conductors shall have a current carrying capacity sufficient to carry the load The branch circuit protective devices shall be located in and for each occupancy "(e) Multi -family dwelling H occupancy For multi -family dwelling H occupancy "1 The minimum service requirements for combined unit occupancy load shall be Conduit Conductors 12" trade size 3 No 1 AWG "2 The minimum feeder or sub -feeder for each individual occupancy shall be Raceway 3/4" trade size Conductors 3 No 8 AWG Switch 60 Ampere Circuit breaker 40 Ampere '3 Service entrance conductors shall have a current carrying capacity sufficient to carry the load and in no case smaller than ##1 AWG Branch Circuit protective devices shall be located in and for each multi -family occupancy with kitchen facilities for cooking (f) Rough Inspection Service shall be complete at the time of rough inspection "FURTHER SCOPE All electrical, telephone, CATV and similar service wires or cables carrying below 34 K V capacity which provide direct service to the property being developed shall, within the exterior boundary lines of such property be installed underground Risers on poles and buildings are permitted and shall be provided by the developer or owner onto the pole which provides service to said property Utility service poles may be placed on the rear of the property to be developed, only for the purpose of terminating underground facilities The developer or owner is responsible for complying with the requirements of the utility companies for the installation of such facilities "For the purpose of this Section, appurtenances and associated equipment such as but not limited to, surface mounted transformers, pedestal mounted terminal boxes and meter cabinets, and concealed ducts in an underground system may be placed above ground The Planning Commission may waive the requirements of this section if topography, soil or any other conditions make such underground installation impossible or impractical " SECTION 2 If any section subsection, sentence, clause, phrase or portion of this Ordinance is for any reason held to be invalid or unconsti- tutional by the decision of any court of competent jurisdiction, such decision shall not affect the validity of the remaining portions of this Ordinance The City Council of the City of Cypress hereby declares that it would have adopted this Ordinance and each section, subsection, sentence, clause, phrase or portion thereof, irrespective of the fact that any one or more sections subsections, clauses, phrases or portions be declared invalid or unconstitutional PASSED AND ADOPTED by the City Council of the City of Cypress, at an adjourned regular meeting held on the 15th day of July, 1968 MAYOR OF THE CITY OF CYPRESS ATTEST' CITY CLERK OF 1`H CIT OF CYPRESS STATE OF CALIFORNIA ) SS COUNTY OF ORANGE ) I, DARRELL ESSEX, City Clerk of the City of Cypress, DO HEREBY CERTIFY that the foregoing Ordinance was adopted at an adjourned regular meeting of the said City Council held on the 15th day of July, 1968, by the following vote AYES" 4 COUNCILMEN Harvey, Kanel Noe and Bowen NOES 0 COUNCILEMN: None ABSENT. 1 COUNCILMEN • Kanode CICLERK iTHE CITY OF CYPRESS Ordinance No. 3R1